BLHFV - CARBON DISULFIDE
- MSDS: BLHFV
- Manufacturer: SPECTRUM CHEMICAL MANUFACTURING CORP
- Product Name: CARBON DISULFIDE
- National Stock Number: 6810-00-112-6000
Product Identification
Product ID:CARBON DISULFIDE
MSDS Date:01/01/1987
FSC:6810
NIIN:00-112-6000
MSDS Number: BLHFV
Responsible Party
GARDENA, CA 90248-2027
US
Emergency Phone: 213-516-8000
Info Phone: 213-516-8000
Cage: 63415
Contractor
Telephone: 310-516-9843
Cage: 63415
Ingredients
CARBON DISULFIDE (SARA III)
CAS: 75-15-0
RTECS: FF6650000
Fraction By Weight: 100%
OSHA PEL 20 PPM
ACGIH TLV: S, 10 PPM; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CARBON DISULFIDE IS ABSORBED VERY
RAPIDLY THROUGH THE SKIN.
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:VOMITING, DIARRHEA, DEPRESSION, LOSS OF
CONSCIOUSNESS,CONVULSIONS, RESPIRATORY PARALYSIS AND POSSIBLE
DEATH. ACTS ON CENTRAL NERVOUS SYSTEM.
Medical Cond Aggravated by Exposure:NONE GIVEN BY MANUFACTURER
(SUPPLIER).
First Aid
First Aid:EYE:FLUSH W/WATER 15 MIN, HOLD LIDS OPEN. SKIN:WASH WITH
SOAP & WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE
REUSE. INHALED:REMOVE TO FRESH AIR. RESTORE BREATHING IF
NECESSARY. GET MEDICAL CARE. INGESTED:GET IMMEDIATE MEDICAL CARE.
GIVE NOTHING BY MOUTH IF UNCONSCIOUS. IF SYMPTOMS PERSIST OR ARE
SEVERE,SEE A DOCTOR.
Fire Fighting
Flash Point Method:CC
Flash Point:=-30.C, -22.F
Autoignition Temp:Autoignition Temp Text:UNKNON
Lower Limits:1.0
Upper Limits:50.0
Extinguishing Media:USE WATER FOG OR SPRAY, CARBON DIOXIDE, OR DRY
CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. EVACUATE AREA. COOL
FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.
Accidental Release
Spill Release Procedures:ALLOW TO EVAPORATE OR WIPE/SOAK UP WITH CLOTH
OR PAPER TOWEL OR INERT ABSORBENT. PUT IN DISPOSAL CONTAINER.
REMOVE RESIDUE WITH WATER.
Neutralizing Agent:NONE
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. PROTECT
CONTAINERS FROM PHYSICAL DAMAGE.
Other Precautions:NONE.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR
OR RESPIRATOR FOR ORGANIC VAPOR/MIST IF EXPOSURE IS ABOVE THE
TLV/PEL. SEE 29 CFR 1910.134 FOR REGULATIONS PERTAINING TO
RESPIRATOR USE.
Ventilation:USE LOCAL EXHAUST AS NEEDED TO CONTROL EXPOSURE BELOW
PEL/TLV.
Protective Gloves:NEOPRENE, OR OTHER IMPERVIOUS
Eye Protection:SPLASH GOGGLES AND/OR FACE SHIELD
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
IMPERVIOUS CLOTHING AND APRON AS REQUIRED.
Work Hygienic Practices:CARBON DISULFIDE IS ABSORBED RAPIDLY THROUGH
THE SKIN. USE STRICT CHEMICAL HYGIENE PRACTICE. AVOID SKIN CONTACT.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:F5
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=46.1C, 115.F
Vapor Pres:400 MM
Vapor Density:2.67
Spec Gravity:1.26
Solubility in Water:0.22%
Appearance and Odor:CLEAR LIQUID, UNPLEASANT ODOR
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
AZIDES
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
OF IGNITION
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SULFUR OXIDES
Disposal
Waste Disposal Methods:DISPOSE I/A/W ALL FEDERAL, STATE AND LOCAL
REGULATIONS. MANUFACTURER MAKES NO SUGGESTIONS AS TO DISPOSAL
PROCEDURE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.